变量名 | 描述 | 单位 | 设计值 | 模型值 | 误差 |
tfr001tfl401rezhttds | 4A主给水出口温度 | ℃ | 156.2 | 156.81 | 0.39% |
tfr001bnd1003flowpb | 4A疏水流量 | kg/s | 25.167 | 25.1729 | 0.023% |
tfr001tfl401rezhttd | 4A疏水温度 | ℃ | 135.5 | 135.5123 | 0.009% |
tfr001bnd1003hpp | 4A疏水焓值 | kj/kg | 570.1 | 572.5267 | 0.43% |
tfr001tfl301rezhttds | 3A主给水出口温度 | ℃ | 132.3 | 132.7803 | 0.36% |
tfr001bnd1007flowpb | 排出3A疏水流量 | kg/s | 61.634 | 61.6295 | −0.007% |
tfr001tfl301rezhttd | 排出3A疏水温度 | ℃ | 134.3 | 134.3648 | 0.048% |
tfr001tfl301rezhthl | 排出3A疏水焓值 | kj/kg | 564.7 | 565.0814 | 0.068% |
tfr001tfr301bazopkbot | TFR301ba压力 | Kpa | 350 | 350.7758 | 0.22% |
tfr301baremrlevel | TFR301ba液位 | mm | — | 11.9 | — |
tfr001bnd1008flowpb | 进入TFR301ba流量 | kg/s | 61.634 | 61.6298 | −0.0068% |
tfr001bnd1013flowpb | 排出TFR301ba流量 | kg/s | 61.634 | 61.6298 | −0.0068% |
tfr004tfl201re_szhttds | 2A主给水出口温度 | ℃ | 95.2 | 95.21001 | 0.01% |
tfr004bnd1001flowpb | 排出2A疏水流量 | kg/s | 43.254 | 43.254 | 0 |
tfr004tfl201re_szhttd | 排出2A疏水温度 | ℃ | 96.7 | 96.84927 | 0.15% |
tfr004tfl201re_szhthd | 排出2A疏水焓值 | kj/kg | 405 | 405.7799 | 0.193% |
tfr004tfl101re_szhttds | 1A主给水出口温度 | ℃ | 54.7 | 54.81776 | 0.21% |
tfr004bnd1005flowpb | 排出1A疏水流量 | kg/s | 36.908 | 36.908 | 0 |
tfr004tfl101re_szhthd | 排出疏水流量焓值 | ℃ | 56.2 | 56.31778 | 0.2% |
tfr004tfl101re_szhttd | 排出疏水温度 | kj/kg | 235.4 | 235.66 | 0.11% |