变量名 | 描述 | 单位 | 设计值 | 模型值 | 误差 |
tfr001tfl401rezhttds | 4A主给水出口温度 | ℃ | 157.3 | 157.83 | 0.34% |
tfr001bnd1003flowpb | 4A疏水流量 | kg/s | 26.0394 | 26.0462 | 0.026% |
tfr001tfl401rezhttd | 4A疏水温度 | ℃ | 136.4 | 136.5646 | 0.12% |
tfr001bnd1003hpp | 4A疏水焓值 | kj/kg | 574.1 | 577.1037 | 0.523% |
tfr001tfl301rezhttds | 3A主给水出口温度 | ℃ | 133.2 | 133.5262 | 0.25% |
tfr001bnd1007flowpb | 排出3A疏水流量 | kg/s | 63.7737 | 63.7671 | −0.01% |
tfr001tfl301rezhttd | 排出3A疏水温度 | ℃ | 135.2 | 135.1995 | −0.0004% |
tfr001tfl301rezhthl | 排出3A疏水焓值 | kj/kg | 568.7 | 568.6656 | −0.006% |
tfr001tfr301bazopkbot | TFR301ba压力 | Kpa | 357 | 357.9262 | 0.26% |
tfr301baremrlevel | TFR301ba液位 | mm | — | 22.6 | — |