循环散热日降温公式 | ||||||||||
水的比重ρg (kg/m3) | 进、出水口温差 ΔT (℃) | ΔL (m3/h) | 水的比热W (KJ/Kg∙k) | 混凝土比热C (KJ/Kg∙k) | 混凝土密度P (Kg/m3) | d (天) | 日降温T (℃) | 累计降温(℃) | 绝热温升(℃) | 通水后温升(℃) |
1000 | 4 | 1.9 | 4.2 | 0.85 | 2400 | 1 | 5.0 | 5.0 |
|
|
1000 | 4 | 1.9 | 4.2 | 0.85 | 2400 | 2 | 5.0 | 10.0 |
|
|
1000 | 4 | 1.9 | 4.2 | 0.85 | 2400 | 3 | 5.0 | 15.0 | 33.8 | 18.8 |
1000 | 4 | 1.9 | 4.2 | 0.85 | 2400 | 4 | 5.0 | 20.1 |
|
|
1000 | 4 | 1.9 | 4.2 | 0.85 | 2400 | 5 | 5.0 | 25.1 |
|
|
1000 | 4 | 1.9 | 4.2 | 0.85 | 2400 | 6 | 5.0 | 30.1 | 47.6 | 17.5 |
1000 | 4 | 1.9 | 4.2 | 0.85 | 2400 | 7 | 5.0 | 35.1 |
|
|
1000 | 4 | 1.9 | 4.2 | 0.85 | 2400 | 8 | 5.0 | 40.1 |
|
|
1000 | 4 | 1.9 | 4.2 | 0.85 | 2400 | 9 | 5.0 | 45.1 | 53.2 | 8.0 |
1000 | 4 | 1.9 | 4.2 | 0.85 | 2400 | 12 |
| 45.1 | 55.4 | 10.3 |
1000 | 4 | 1.9 | 4.2 | 0.85 | 2400 | 15 |
| 45.1 | 56.4 | 11.3 |
1000 | 4 | 1.9 | 4.2 | 0.85 | 2400 | 18 |
| 45.1 | 56.7 | 11.6 |
1000 | 4 | 1.9 | 4.2 | 0.85 | 2400 | 21 |
| 45.1 | 56.9 | 11.8 |
1000 | 4 | 1.9 | 4.2 | 0.85 | 2400 | 24 |
| 45.1 | 57.0 | 11.9 |
1000 | 4 | 1.9 | 4.2 | 0.85 | 2400 | 27 |
| 45.1 | 57.0 | 11.9 |
1000 | 4 | 1.9 | 4.2 | 0.85 | 2400 | 30 |
| 45.1 | 57.0 | 11.9 |