桩号 | MIKE11 恒定流 | MIKE11 非恒定流 | HEC-RAS 恒定流 | HEC-RAS 非恒定流 | ⑤ = ① − ② | ⑥ = ③ − ④ | ⑦ = ① − ③ | ⑧ = ② − ④ |
① | ② | ③ | ④ | |||||
0+200 | 507.15 | 507.15 | 507.33 | 507.35 | 0.00 | −0.02 | −0.18 | −0.20 |
0+400 | 506.77 | 506.77 | 506.86 | 506.89 | 0.00 | −0.03 | −0.09 | −0.12 |
0+600 | 506.65 | 506.65 | 506.54 | 506.56 | 0.00 | −0.02 | −0.11 | −0.05 |
0+800 | 506.32 | 506.32 | 506.33 | 506.36 | 0.00 | −0.03 | −0.01 | −0.04 |
1+000 | 506.03 | 506.03 | 506.05 | 506.08 | 0.00 | −0.03 | −0.02 | −0.05 |
1+200 | 505.61 | 505.60 | 505.73 | 505.76 | 0.00 | −0.03 | −0.13 | −0.16 |
1+400 | 505.06 | 505.06 | 505.33 | 505.37 | 0.00 | −0.04 | −0.27 | −0.31 |
1+600 | 504.64 | 504.64 | 504.66 | 504.72 | 0.00 | −0.06 | −0.02 | −0.08 |
1+800 | 504.10 | 504.09 | 504.33 | 504.36 | 0.00 | −0.03 | −0.23 | −0.27 |
2+000 | 503.47 | 503.46 | 503.83 | 503.87 | 0.00 | −0.04 | −0.37 | −0.41 |
2+200 | 502.81 | 502.80 | 503.08 | 503.09 | 0.00 | −0.01 | −0.27 | −0.29 |
2+400 | 502.28 | 502.28 | 502.41 | 502.45 | 0.00 | −0.04 | −0.13 | −0.17 |
2+600 | 502.03 | 502.03 | 501.74 | 501.76 | 0.00 | −0.02 | 0.29 | 0.27 |
2+800 | 501.66 | 501.66 | 501.45 | 501.46 | 0.00 | −0.01 | 0.21 | 0.20 |
3+112 | 501.00 | 501.00 | 501.00 | 501.00 | 0.00 | 0.00 | 0.00 | 0.00 |