SVM

Precision

Recall

F1 score

Accuracy

Normal

100%

100%

100%

fatigue

88%

56%

0.77

extreme fatigue

69%

93%

79%

Total

84%

RF

Precision

Recall

F1 score

Accuracy

Normal

100%

100%

100%

fatigue

83%

70%

76%

extreme fatigue

76%

86%

81%

Total

86%

DF

Precision

Recall

F1 score

Accuracy

Normal

100%

100%

100%

fatigue

89%

85%

87%

extreme fatigue

86%

90%

88%

Total

92%