| 风压(kN/m2) | 塔高 | ||
| 50 m | 40 m | 30 m | |
| 0.95 | TD-10000-1300/1500-14 | ||
| TD-10000-1150/1300-12 | TD-10000-1150/1300-12 | ||
| TD-10000-1000/1150-12 | TD-10000-1000/1150-12 | TD-10000-850/1000-10 | |
| TD-10000-850/1000-10 | TD-10000-850/1000-10 | TD-10000-650/850-8 | |
| TD-10000-650/850-8 | TD-10000-650/850-8 | TD-10000-500/650-6 | |
| 0.85 | TD-10000-1300/1450-14 | ||
| TD-10000-1150/1300-12 | TD-10000-1050/1250-12 | ||
| TD-10000-1000/1150-12 | TD-10000-850/1050-10 | TD-10000-850/950-10 | |
| TD-10000-850/1000-10 | TD-10000-650/850-8 | TD-10000-650/850-8 | |
| TD-10000-650/850-8 | TD-10000-500/650-6 | TD-10000-500/650-6 | |
| 0.75 | TD-10000-1300/1400-14 | ||
| TD-10000-1150/1300-12 | TD-10000-1000/1200-12 | ||
| TD-10000-1000/1150-12 | TD-10000-850/1000-10 | TD-10000-700/900-10 | |
| TD-10000-850/1000-10 | TD-10000-650/850-8 | TD-10000-500/700-8 | |
| TD-10000-650/850-8 | TD-10000-500/650-6 | TD-10000-400/500-6 | |
| 0.65 | TD-10000-1150/1300-12 | ||
| TD-10000-1000/1150-12 | TD-10000-1000/1150-12 | ||
| TD-10000-850/1000-10 | TD-10000-850/1000-10 | TD-10000-700/850-10 | |
| TD-10000-650/850-8 | TD-10000-650/850-8 | TD-10000-500/700-8 | |
| TD-10000-500/650-6 | TD-10000-500/650-6 | TD-10000-400/500-6 | |
| 0.55 | TD-10000-1150/1300-12 | ||
| TD-10000-1000/1150-12 | TD-10000-850/1050-10 | ||
| TD-10000-850/1000-10 | TD-10000-700/850-10 | TD-10000-650/850-8 | |
| TD-10000-650/850-8 | TD-10000-500/700-8 | TD-10000-500/650-6 | |
| TD-10000-500/650-6 | TD-10000-400/500-6 | TD-10000-400/500-6 | |
| 0.45 | TD-10000-1000/1200-12 | ||
| TD-10000-850/1000-10 | TD-10000-850/1000-10 | ||
| TD-10000-650/850-8 | TD-10000-650/850-8 | TD-10000-650/800-8 | |
| TD-10000-500/650-6 | TD-10000-500/650-6 | TD-10000-500/650-6 | |
| TD-10000-400/500-6 | TD-10000-400/500-6 | TD-10000-400/500-6 | |
| 0.35 | TD-10000-1000/1150-12 | ||
| TD-10000-850/1000-10 | TD-10000-850/950-10 | ||
| TD-10000-650/850-8 | TD-10000-650/850-8 | TD-10000-650/750-8 | |
| TD-10000-500/650-6 | TD-10000-500/650-6 | TD-10000-500/650-6 | |
| TD-10000-400/500-6 | TD-10000-400/500-6 | TD-10000-400/500-6 | |